Cureus | Autologous Nonvascularized Fibula Graft and Locking Compression Plating for Failed Fixation of Humeral Shaft With Atrophic Gap Nonunion

2022-04-21 07:23:50 By : Mr. Mr Leed

"Never doubt that a small group of thoughtful, committed citizens can change the world. Indeed, it is the only thing that ever has."

Cureus is on a mission to change the long-standing paradigm of medical publishing, where submitting research can be costly, complex and time-consuming.

The SIQ for this article will be revealed

gap nonunion, humeral fracture, nonunion, locking compression plating, humerus, autologous fibula graft

Karan Shetty, Naga Cheppalli , Deepak Kaki

Cite this article as: Shetty K, Cheppalli N, Kaki D (April 19, 2022) Autologous Nonvascularized Fibula Graft and Locking Compression Plating for Failed Fixation of Humeral Shaft With Atrophic Gap Nonunion. Cureus 14(4): e24293. doi:10.7759/cureus.24293

The surgical treatment of humeral shaft atrophic, gap nonunion following failed surgical fixation is challenging. We intended to evaluate the surgical outcome of failed fixation of humeral shaft atrophic, gap nonunions using locking compression plate (LCP) and autologous nonvascularized fibular graft (ANVFG) and autologous iliac crest bone graft (AICBG).  

Through our database search between 2015 and 2018, we identified 12 patients with humeral shaft atrophic, gap nonunions with failed surgical fixation underwent open reduction and internal fixation using LCP with autologous fibula graft and iliac crest cancellous bone graft.  

We have followed all twelve patients for a minimum period of 24 months. All patients had radiological and clinical union with a mean time to union of 17 weeks. In one case superficial surgical site infection was noted and successfully treated with intravenous antibiotics, and in another, transient peroneal nerve palsy was identified and resolved in six months.  

LCP with ANVFG and AICBG is a reliable option for “complex” diaphyseal humerus atrophic and gap non unions, especially with significant bone loss. This construct provides mechanical stability and supports biological healing in these complex fractures.

Nonunion of humeral shaft fractures after failed osteosynthesis can be challenging to treat, especially in the presence of disuse osteoporosis, osteolysis secondary to implant loosening, or associated with significant bone loss and gap. Multiple surgical options have been described in the literature including open reduction and internal fixation with dynamic compression plate (DCP), locking compression plate (LCP) interlocking nail (ILN), and external fixator [1]. Autologous nonvascularized fibular graft (ANVFG) has been used in combination with plating [2-4]. This construct improves biomechanical strength and provides enhanced biology for gap and atrophic nonunions in long bones. The purpose of this study is to assess the outcome of surgically treated “complex” humerus shaft nonunion (failed primary osteosynthesis, with atrophic and gap nonunion) using a combination of LCP, ANVFG with autologous iliac crest bone graft (AICBG).

Institution Ethical Committee approval was obtained for this retrospective study. Patients' informed consent is taken at the time of collection of final follow-up and collection of DASH scores. Patients were identified by searching through our institute's register from 2015 to 2018 for operated cases for humeral fracture nonunion fixation. We also searched through the surgeon's operative logbook to avoid any missing data. (No electronic records are available at our institution). We defined “complex humerus nonunion” as an established nonunion (patient presented clinically with painless abnormal mobility, with radiological signs suggesting the fracture failed to unite) of the humeral shaft after failed osteosynthesis and associated with the significant gap (minimum 5 mm), and osteolysis at the screw and bone interface with atrophic fracture end. We included only “complex” humeral nonunion for this study.

We identified 12 patients and the senior surgeon determined that all these patients needed additional mechanical stabilization in the form of intramedullary cortical strut in addition to locking compression plating (LCP). As the bone bank is not available and affordable in our region, the senior surgeon elected to use ipsilateral fibula as a nonvascularized cortical strut graft to provide additional mechanical stability and autologous iliac crest cancellous graft for osteoinduction at the fracture site along with LCP. Closure of the gap is performed whenever possible. All 12 patients were followed up regularly clinically and radiologically for a minimum period of two years. There was no loss of follow-up. We excluded infected nonunion, and aseptic nonunion after conservative management for this study.

All cases were operated on under general anesthesia. The surgical approach and hence patient position were based on the previous surgical approach. One team of surgeons harvested fibular graft, while the other team removed humeral hardware and prepared the nonunion site. Fibular graft harvesting was performed under a tourniquet. The ipsilateral knee was flexed and the fibula was approached via a lateral approach. The graft was to be harvested in the central third of the fibula, ensuring at least 7 cm of the fibula is preserved proximally and distally to avoid peroneal nerve injury and ankle/knee instability. The length of the harvested graft ranged from 9-15 cm. Multiple drill holes were made at desired levels proximally and distally before completing the osteotomy with osteotomes (Figures 1A-1D).

Humerus was exposed following the previous surgical approach used for primary fixation. Previous implants were removed, soft-tissue scarring and intervening fibrous tissue were excised and the bone was debrided. Radial nerve neurolysis was done whenever necessary. Fracture ends were freshened. With serial reaming using rigid reamers, the medullary canal was recanalized in both fragments. The fibular graft was prepared such that its diameter was snuggly fitting the endosteal diameter of the reamed humerus. The center of the graft was marked and placed as an intramedullary strut, ensuring the center was at the level of the fracture. The average length of graft harvested was 11.66 cm, and the average length of graft used was 10.58 cm. Slivers of the harvested fibular strut obtained during graft preparation were included with iliac crest graft autograft at nonunion. End-to-end compression was achieved in nine cases with an articulated tensioner and using dynamic holes and nonlocking screws on either fragment, while three cases with severe preoperative shortening required structural tricortical iliac crest autograft to bridge the gap across the ends. Iliac crest cancellous bone grafting was done at the graft-humerus interface in all cases, to augment chances for the union. Fixation was done with a 10-holed 4.5 mm LCP, contoured to match the cortical surface. In all the cases, the proximal fragment was stabilized with eight cortices, however, based on the available bone distally four to eight humeral cortices were fixed with locking screws. Emphasis was placed on ensuring at least two screws in each fragment passing through fibular graft in addition to humeral cortices.

Postoperatively, the limb was immobilized in a sling for four weeks. Four weeks post-operatively, active-assisted shoulder and elbow exercises were started. Patients were followed up once every four weeks until the radiological union was seen and then at three months intervals. The minimum follow-up was 24 months. Functional assessment was done by using the disabilities of the arm, shoulder, and hand (DASH) score both preoperatively and postoperatively at the final follow-up.

Twelve patients were identified as fulfilling the criteria for “complex” humeral nonunion following failed primary osteosynthesis. The mean age of the study group was 50.7 (±6.92) years. Duration of nonunion, i.e., time since index surgery ranged from six months to three years. The bone gap ranged from 5 mm to 60 mm. Patients had undergone at least one to three prior surgeries. All the fractures were at the level of the middle third except one which was at the junction of the middle third and distal third. We excluded any patients with signs suggestive of infection. ESR and CRP values were checked for all patients to rule out subclinical infection. When in doubt, intraoperative tissue was sent for cultures and treated with antibiotics until the culture results are back (2/12 patients). Each patient was treated with open reduction and internal fixation using 10 holed 4.5 mm LCP with Autologous fibular graft and iliac crest cancellous bone graft in all cases. All patients were followed up for a minimum period of two years. All patients had a clinical and radiological union. The radiological union was defined by the presence of fracture union in at least three of the four cortices in orthogonal x-ray views. No patient-reported pain at the fracture site. Meantime to radiological union was 17 weeks (range, 12-24 weeks). When clinically measured the average arm shortening was 8 mm (range, 5 to 20 mm) compared to the contralateral side. Shoulder abduction and flexion were found to be reduced by an average of 15 degrees each, postoperatively. However, preoperative flexion stiffness of the elbow resolved partially in all cases. Patient demographics, surgical indications, and details of the surgery with the outcome are presented (Table 1) and case examples of radiographs are presented (Figures 2A, 2B, 3A-3C). All patients returned to near normal pre-injury activity levels, with DASH scores improving from a preoperative average of 61.0 ± 6.7 (range, 48.1 - 68.2) to an average final follow-up DASH score of 28.8 ± 4.4 (range, 19.9-33.3), with a mean improvement of 32.23 (Figure 4). All patients were satisfied with the treatment with none having any wound complications, except one patient who developed a superficial surgical wound infection which resolved with debridement and intravenous antibiotics. One other patient developed transient peroneal nerve palsy which showed signs of recovery in seven weeks and completely resolved in six months. No graft site morbidity was noted at the final follow-up.

DASH - disabilities of the arm, shoulder, and hand

Nonunion of the humeral shaft is likely to be related to the pattern of fracture, soft-tissue interposition, and quality of primary fixation [5]. Failure to unite after surgical treatment may be due to poor contact between the fracture ends, inadequate stabilization, devitalization of bone, osteopenia, and bone defects. Smoking, obesity, alcoholism, diabetes mellitus, and method of treatment may also be contributory factors [6]. We defined “complex humerus nonunion” as the established nonunion of the humeral shaft after failed osteosynthesis, and associated with significant gap nonunion (at least 5 mm), and osteolysis at the screw and bone interface. The patients included in this study had atrophic type gap nonunion, with failed osteosynthesis attempts from these aforementioned local and general factors. Local osteoporosis, mostly secondary to disuse, compounds the choice of surgical treatment in these patients. Often, these patients had implant breakage, metal debris, and metallosis, with scalloping around the screws and ballooning of the cortex. This poses a reconstructive challenge, and various options have been described for fracture fixation earlier in the literature.

Numerous surgical options (plating, nailing, external fixator) have been described to treat humeral nonunion with bone defects such as primary shortening, one stage cancellous bone graft, cancellous bone graft in two stages (after induced membrane), pedicle bone transfer (free border of the scapula, ninth rib), periosteal free flap transfer or bone morphogenetic protein [7-10].

We choose LCP as our treatment option for fracture stabilization as we are more familiar with this approach. In our hands, we believe that the ILN is not suitable for some distal fractures, violates rotator cuff integrity, and depends on an image intensifier and technician (adding to the cost of the procedure) [11]. Bone transport using distraction histogenesis with Ilizarov fixators or limb reconstruction system has a certain appeal, but cost, technically demanding nature of this technique, the commitment of time, and complications have limited its acceptance [12]. Dynamic compression plating has been described and high rates of the union have been claimed. It provides compression at the fracture site, with correction of axial malalignment. It can be applied with great success provided the bone quality is reasonable. However, most cases of implant failure have poor bone quality and screw purchase, where instead of DCP, LCP may be a reliable option [13].

LCPs are very promising, especially in the presence of nonunion and osteopenia by providing a rigid, angle-stable construct [14]. Osteopenia as a result of disuse, due to a generalized metabolic cause and previous implant stress shielding along with previous screw holes will interfere with the strength and purchase of the screws inserted subsequently during osteosynthesis. The concept of quadricortical plating through intramedullary fibular strut graft was first described by Wright et al. [15]. This improved mechanical environment may reduce the risk of fibrous nonunion or failed fixation that can occur as a result of excessive motion and osteoporotic bone. Iliac crest bone graft (ICBG) has no inherent mechanical strength to withstand forces until fracture union and also contributes to significant graft harvest site morbidity. In our case series, we elected to use fibular graft for all the cases to add additional mechanical strength to the construction. An autologous iliac crest graft is added additionally at the fracture site. No deliberate shortening is performed. The nonvascularized fibula is easy to harvest with minimal harvest site morbidity and does not need expertise with microsurgical skills. The cortical bone affords immediate structural continuity and stability at the fracture site post-fixation. The fibula functions as a triflanged nail and engages the host bone firmly thus making it the most suitable donor bone for the reconstruction of defects in a long bone [16]. Although it is believed that cortical bone grafts frequently fail as surrounding soft tissue cannot provide adequate vascularity for the incorporation of graft, we did not find any graft being resorbed or failing.

While compared to surgical options including allografts, bone transport with external fixators, induced membrane technique, and BMPs, autograft with fibula is a significantly more cost-effective procedure. Even though the superiority of autologous non vascularized autologous fibular graft cannot be proven over allogenous fibular graft [16] or vascularized fibular graft, we believe this is an excellent option, especially in countries where the bone banking system is not well developed and there is a dearth of specialists with microsurgical skills. Therefore, this technique with fibular autograft will have greater acceptance as a reliable procedure that can be performed at most centers without significant financial burden to the patient (in countries where health care cost is directly paid by the patients). A possible theoretical disadvantage of ANVFG includes disruption of both the periosteal and the endosteal blood supply. Donor site morbidity is another disadvantage, although the impairment is often minimal [17-19]. Free nonvascularized fibular grafts are known to be at risk for necrosis resulting in absorption and nonincorporation to the host bone. However, it has been reported that if the autologous bone graft is fixed to the recipient's bone immediately after it is retrieved, the graft will survive. Immediate fixation of the graft at the recipient site allows the cells in and over the graft to draw oxygenation and nutrition from the blood, thereby preserving their osteogenic properties [17]. Complications reported from this technique include stress supracondylar fracture, radial nerve palsy, iatrogenic splinter during implant removal, transient peroneal nerve injury, and adhesive capsulitis of the shoulder [20]. However, we did not incur these problems.

The results in our series with minimal complications favor this easy and reliable option. One patient developed a superficial wound infection which was controlled with debridement with implant retention and parenteral antibiotics. Another patient developed transient peroneal nerve palsy which recovered completely in six months. 

This study has significant limitations. This is a retrospective case series with a limited number of patients (12) performed at a single center with limited resources (nonavailability of allograft and bone morphogenic protein), by a single surgeon. 

Based on our experience, we conclude that autologous nonvascularized fibular strut graft with iliac crest cancellous autograft and fixation with LCP is a reliable option for treating “complex” diaphyseal humerus nonunion with significant bone loss and osteopenia. The addition of free fibular graft provided additional mechanical stability in osteoporotic bone, while AICBG improved the biologic milieu of repaired fracture. This technique resulted in a mean improvement of DASH score by 32.33, all patients returned to pre-injury level and resulted in 100% radiological union despite multiple previous failed fixations. This procedure is reproducible and can be performed with minimal morbidity. This procedure can be one of the treatment options in less resourceful regions (where the bone bank/allograft/BMP is not available).

Orthopaedics, Sapthagiri Institute of Medical Science and Research Centre, Bengaluru, IND

Orthopaedics, University of New Mexico School of Medicine, Albuquerque, USA

Orthopaedics, Balaji Institute of Surgery, Research and Rehabilitation for the Disabled (BIRRD) Hospital, Tirupati, IND

Human subjects: Consent was obtained or waived by all participants in this study. Institutional Ethics Committee of Sri Balaji Institute of Surgery, Research and Rehabilitation for the Disabled, TID, Tirupati issued approval NA. Animal subjects: All authors have confirmed that this study did not involve animal subjects or tissue. Conflicts of interest: In compliance with the ICMJE uniform disclosure form, all authors declare the following: Payment/services info: All authors have declared that no financial support was received from any organization for the submitted work. Financial relationships: All authors have declared that they have no financial relationships at present or within the previous three years with any organizations that might have an interest in the submitted work. Other relationships: All authors have declared that there are no other relationships or activities that could appear to have influenced the submitted work.

Shetty K, Cheppalli N, Kaki D (April 19, 2022) Autologous Nonvascularized Fibula Graft and Locking Compression Plating for Failed Fixation of Humeral Shaft With Atrophic Gap Nonunion. Cureus 14(4): e24293. doi:10.7759/cureus.24293

Peer review began: April 13, 2022 Peer review concluded: April 14, 2022 Published: April 19, 2022

© Copyright 2022 Shetty et al. This is an open access article distributed under the terms of the Creative Commons Attribution License CC-BY 4.0., which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.

This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.

DASH - disabilities of the arm, shoulder, and hand

Scholarly Impact Quotient™ (SIQ™) is our unique post-publication peer review rating process. Learn more here.

This link will take you to a third party website that is not affiliated with Cureus, Inc. Please note that Cureus is not responsible for any content or activities contained within our partner or affiliate websites.

Scholarly Impact Quotient™ (SIQ™) is our unique post-publication peer review rating process. SIQ™ assesses article importance and quality by embracing the collective intelligence of the Cureus community-at-large. All registered users are invited to contribute to the SIQ™ of any published article. (Authors cannot rate their own articles.)

High ratings should be reserved for work that is truly groundbreaking in its respective field. Anything above 5 should be considered above average. While all registered Cureus users can rate any published article, the opinion of domain experts is weighted appreciably more than that of non-specialists. An article’s SIQ™ will appear alongside the article after being rated twice and is recalculated with each additional rating.

Visit our SIQ™ page to find out more.

Scholarly Impact Quotient™ (SIQ™) is our unique post-publication peer review rating process. SIQ™ assesses article importance and quality by embracing the collective intelligence of the Cureus community-at-large. All registered users are invited to contribute to the SIQ™ of any published article. (Authors cannot rate their own articles.)

Already have an account? Sign in.

Please note that by doing so you agree to be added to our monthly email newsletter distribution list.

By joining Cureus, you agree to our Privacy Policy and Terms of Use.